Usage
as.echosounder(time, depth, a, src = "", sourceLevel = 220, receiverSensitivity = -55.4, transmitPower = 0, pulseDuration = 400, beamwidthX = 6.5, beamwidthY = 6.5, frequency = 41800, correction = 0)
Arguments
depth
depths of samples within pings
src
optional string indicating data source
sourceLevel
source level, in dB (uPa at 1m), denoted sl
in [1
p15], where it is in units 0.1dB (uPa at 1m)
receiverSensitivity
receiver sensivity of the main element, in
dB(counts/uPa), denoted rs
in [1 p15], where it is in units of
0.1dB(counts/uPa)
transmitPower
transmit power reduction factor, in dB, denoted
tpow
in [1 p10], where it is in units 0.1 dB.
pulseDuration
duration of transmited pulse in us
beamwidthX
x-axis -3dB one-way beamwidth in deg, denoted bwx
in [1 p16], where the unit is 0.2 deg
beamwidthY
y-axis -3dB one-way beamwidth in deg, denoted bwx
in [1 p16], where the unit is 0.2 deg
frequency
transducer frequency in Hz, denoted fq
in [1 p16]
correction
user-defined calibration correction in dB, denoted
corr
in [1 p14], where the unit is 0.01dB.