flowrat: Calculation of required spray nozzle flow

Description

This is a function to determine the required flow rate of a spray nozzle

Usage

flowrat(Q, q, V, W = 50)

Value

Returns values for flow, application rate, sprayer speed, spacing between spray tips

Arguments

Q

Application rate (L/ha)

q

Nozzle flow (L/min)

V

Sprayer speed (km/h)

W

Spacing between spray nozzles (cm)

Author

Rodrigo Yudi Palhaci Marubayashi, marubayashi@uel.br

Gabriel Danilo Shimizu

Otavio Jorge Grigoli Abi Saab

Details

Application rate (L/ha): $$Q=\frac{60000*q}{V*W}$$ Nozzle flow (L/min): $$q=\frac{Q*(V*W)}{60000}$$ Sprayer speed (km/h): $$V=\frac{\frac{60000*q}{Q}}{W}$$ Spacing between spray nozzles (m): $$W=\frac{\frac{60000*q}{Q}}{V}$$

References

ANDEF Associacao Nacional de Defesa Vegetal. Manual de tecnologia de aplicacao de produtos fitossanitarios. Campinas: Linea Creativa, 2004. 50p.

BOLLER, W.; RAETANO, C. G. Bicos e pontas de pulverizacao de energia hidraulica, regulagens e calibracao de pulverizadores de barras. In: ANTUNIASSI, U. R.; BOLLER, W. (Organizadores). Tecnologia de aplicacao para culturas anuais. Passo Fundo: Aldeia Norte; Botucatu: FEPAF, 2011. p.51-82.

SPRAYING SYSTEMS CO. Catalogo 51A-PT - Produtos de pulverizacao para agricultura. Wheaton: Spraying Systems Co., 2014. 160p.

See Also

flowpres product

Examples

Run this code
flowrat(Q = 190,q = NA,V = 10,W = 50)