Learn R Programming

DVHmetrics (version 0.3.4)

getTCP: Tumor control probability (TCP)

Description

Calculate tumor control probability (TCP) from Lyman's probit model, Niemierko's logit model, or Kaellman's Poisson model. May be based on EQD2.

Usage

getTCP(x, TCPtcd50=NULL, TCPm=NULL, TCPn=NULL, TCPgamma50=NULL,
       EUDa=NULL, EUDfn=NULL, EUDab=NULL,
       TCPtype=c("probit", "logit", "poisson"), ...)

Arguments

x
One cumulative DVH (object of class DVHs, multiple cumulative DVHs from one patient with multiple structures (object of class DVHLst), or multiple cumulative DVHs from many patients, each with multiple structures (object of class
TCPtcd50
Tolerance dose with 50% tumor control probability.
TCPm
Probit/logit Parameter m. Equal to 1 / (NTCPgamma50*sqrt(2*pi)).
TCPn
Parameter n. Equal to 1/a with exponential gEUD paramter a.
TCPgamma50
Poisson parameter gamma50. Equal to 1 / (NTCPm*sqrt(2*pi))
EUDa
If gEUD should be based on EQD2: Exponential parameter a.
EUDfn
If gEUD should be based on EQD2: Number of fractions.
EUDab
If gEUD should be based on EQD2: alpha/beta ratio for the relevant tissue.
TCPtype
"probit" - Lyman probit model, "logit" - Niemierko logit model, "poisson" - Kaellman Poisson (relative seriality) model.
...
Ignored. Used to catch additional arguments passed from getMetric.

Value

  • A data frame with variables TCP, patID, and structure.

Details

For DVH reduction, gEUD is used. This is equivalent to the Kutcher-Burman DVH reduction scheme.

References

Kaellman, P., Agren, A., & Brahme, A. (1992). Tumor and normal tissue responses to fractionated non-uniform dose delivery. International Journal of Radiation Biology, 62(2), 249-262. Kutcher, G. J., Burman, C., Brewster L., Goitein, M., & Mohan, R. (1991). Histogram reduction method for calculating complication probabilities for threedimensional treatment planning evaluations. International Journal of Radiation Oncology Biology Physics, 21(1), 137-146. Lyman, J. T. (1985). Complication probability as assessed from dose volume histograms. Radiation Research, 104(2), S13-19. Niemierko, A. (1999). A generalized concept of equivalent uniform dose. Medical Physics, 26(6), 1100. Rancati et al. (2004). Fitting late rectal bleeding data using different NTCP models: results from an Italian multi-centric study (AIROPROS0101). Radiotherapy Oncology, 73, 21-32.

See Also

getNTCP, getEUD, getMetric

Examples

Run this code
getTCP(dataMZ[[1]],
       TCPtcd50=40, TCPm=0.6, TCPn=0.5, TCPtype="probit")

Run the code above in your browser using DataLab