- dat
a data frame with reactor identification code; time of measurement (as numeric
, or POSIX
); and measured pressure in pres.unit
.
See Details section for details on units.
Additional columns can be present--these will be returned in the output data frame.
See data.struct
argument for details on how data frames are structured.
- comp
(optional) a data frame with the columns reactor identification code; time of measurement, (as numeric
, or POSIX
); and methane concentration within dry biogas as a mole fraction, considering only methane and carbon dioxide (unless cmethod = "total"
) or a single numeric value.
If omitted, cumulative biogas volume will still be calculated and returned (but no methane data will be returned).
The names of these columns are specified with id.name
, time.name
, and comp.name
.
Default is NULL
.
- temp
the temperature at which headspace pressure was measured.
A length-one numeric vector or length-one character vector referring to a column in dat
.
Degrees Celcius by default (see unit.temp
argument).
- interval
do biogas pressure measurements represent production only from the time interval between observations (default)?
interval = FALSE
means measured pressure is cumulative.
For mixed manometric measurements (some observations vented, some not), use interval = TRUE
, include a column for pres.resid
, and, if composition was only measured for vented observations, use imethod = "f1"
.
Default is TRUE
.
- data.struct
the structure of input data. The default of 'longcombo' means headspace pressure and composition in a single column.
The dat
data frame must have reactor identification code and time columns with names specified with id.name
and time.name
, volume data in a single column with the name specified by pres.name
, and biogas composition in a single column with the name specified by comp.name
For the data.struct = 'long'
option, two separate data frames are needed, one with volume and one with composition.
Each data frame must have reactor identification code and time columns with names specified with id.name
and time.name
.
The dat
data frame must have volume data in a single column with the name specified by pres.name
.
The comp
data frame must have biogas composition in a single column with the name specified by comp.name
.
For the data.struct = 'wide'
option, two separate data frames are needed as in 'long'
, but there are no reactor identification code columns.
Instead, in dat
, volume data are in a separate column for each bottle, and column names are reactor identification codes.
Here, pres.name
should be the name of the first column with volume data.
All following columns are assumed to also have volume data.
And in comp
, biogas composition data are also in a separate column for each bottle, also with reactor identification codes for column names.
Here, comp.name
should be the name of the first column with biogas composition data, as for dat
.
- id.name
name of the reactor identification code column in dat
. Must be the same in all data frames used in the function. Default is "id"
.
- time.name
name of column containing time data in dat
and comp
data frames. Default is "time"
.
- pres.name
name of column containing the primary response variable (pressure) in dat
data frame. Default is dat.type
value. See dat.type
argument.
- comp.name
name of column containing biogas mole fraction of methane in comp
data frame. Default is "xCH4"
. Must be normalised so xCH4 + xCO2 = 1.0 unless cmethod = "total"
.
- pres.resid
headspace pressure after venting.
Either a single numeric value, assumed to be the same for all observations, or the name of a column in dat
that contains these values for each observation.
Can be absolute (default) or gauge depending on the value of absolute
.
Length one numeric or character vector.
- temp.init
initial headspace temperature in unit.temp
units.
Used to determine initial gas volume.
- pres.init
headspace pressure at the begining of the experiment.
Can be absolute (default) or gauge depending on the value of absolute
.
Length one numeric vector.
- rh.resid
relative humidity of the gas in the headspace after venting.
If NULL (default), it is calculated for each interval as the ratio of post- to pre-venting pressure (equivalent to assuming relative water vapor concentration (mixing ratio) is the same before and after venting.
If entered, typically should be 1.0.
Length one numeric vector.
- rh.resid.init
relative humidity of the gas in the headspace at the begining of the experiment.
Typically should be 1.0 (the default).
Length one numeric vector.
- headspace
(optional) a data frame or length-one numeric vector with reactor headspace volume(s).
If a data frame is used, it should at least contain a "id"
(reactor identification code) column (see "id.name"
) and headspace volume column (see vol.hs.name
argument).
Required if cmethod = "total"
.
Default is NULL
.
- vol.hs.name
name of column containing headspace volume data in optional headspace
data frame.
Default is "vol.hs"
.
- absolute
is the headspace pressure measured (pres.name
and pres.resid
values/columns) absolute or gauge pressure?
Default is TRUE
.
- pres.amb
absolute ambient pressure needed to calculate absolute pressure from gauge pressure measurements.
In atmospheres by default (see unit.pres
argument).
Only a single value is accepted.
If ambient pressure differed among measurements, it is necessary to convert pressures to absolute values and use absolute = TRUE
instead.
- cmethod
method for calculating cumulative methane production.
Use "removed"
to base production on xCH4
and gas volumes removed (default).
Use "total"
to base it on the sum of methane removed and methane remaining in the reactor headspace.
For "removed"
, xCH4
should be calculated based on methane and CO2 only (xCH4 + xCO2 = 1.0).
For "total"
, xCH4
should be calculated including all biogas components (CH4, CO2, N2, H2S, etc.) except water.
Length one character vector.
- imethod
method used for interpolation of xCH4
.
This is passed as the method
argument to interp
.
Length one character vector.
Default is "linear"
for linear interpolation.
- extrap
should comp.name
be extrapolated?
Length one logical vector.
This is passed as the extrap
argument to interp
.
Default is FALSE
.
- addt0
is the earliest time in dat
data frame “time zero” (start time)?
If not, this argument adds a row with time.name = 0
for each reactor in order to calculate production rates for the first observation.
This addition is only made when time.name
is numeric
(or integer
).
Length-one logical vector.
Default is TRUE
.
To return these additional rows in the output, see showt0
.
- showt0
should “time zero” rows be returned in the output?
Can be convenient for plotting cumulative volumes.
Only applies if time.name
is numeric
(or integer
).
These rows may have been present in the original data (dat
) or added by the function (see addt0
).
Default value depends on dat
time.name
column content.
If time.name
column is numeric and contains 0 then the default value is TRUE
and otherwise FALSE
.
- std.message
should a message with the standard conditions be displayed?
Default is TRUE
.
- check
should input data be checked for unreasonable values (with warnings)?
Currently only composition values are checked.
Default is TRUE
.
Values are changed if outside 0, 1 (divided by 100).
- temp.std
standard temperature for presentation of biogas and methane results.
Length one numeric vector.
Default value is 0 degrees C (set in stdVol
).
Argument is passed to stdVol
.
- pres.std
standard pressure for presentation of biogas and methane results.
Length one numeric vector.
Default value is 1.0 atm (101325 Pa) (set in stdVol
).
Argument is passed to stdVol
.
- unit.temp
temperature units for temp
and temp.std
arguments.
Default is "C"
.
Argument is passed to stdVol
.
- unit.pres
pressure units for pres
and pres.std
arguments.
Default is "atm"
.
Argument is passed to stdVol
.
- quiet
use to suppress messages. Default is FALSE
.