pk_2cmt_inf_ss: Concentration predictions for 2-compartmental PK model with infusion dosing at steady state
Description
Concentration predictions for 2-compartmental PK model with infusion dosing at steady state
Usage
pk_2cmt_inf_ss(
t = c(0:24),
dose = 100,
t_inf = 1,
tau = 12,
CL = 3,
V = 30,
Q = 2,
V2 = 20,
ruv = NULL
)
Arguments
t
vector of time
dose
dose
t_inf
infusion time
tau
dosing interval
CL
clearance
V
volume of distribution
Q
inter-compartimental clearance
V2
volume of peripheral compartment
ruv
residual variability, specified as list with optional arguments for proportional, additive, or exponential components, e.g. `list(prop=0.1, add=1, exp=0)`