powered by
calcMRT calculates the mean radiant temperature considering mixed convection
calcMRT
calcMRT(tg, ta, vel, x = 0.15)
calcMRT MRT with standard and mixed correction
- a numeric value presenting globe temperature in [degree C]
- a numeric value presenting air temperature in [degree C]
- a numeric value presenting air velocity in [m/s]
- a numeric value presenting globe diamter in [m]
code implementedc into R by Shaomi Rahman and Marcel Schweiker.
aliases MRT
This model has only been validated from x = 0.040m (ping pong ball) to
x = 0.150m (standard globe thermometer) globes
Teitelbaum et al. (2022) <10.1038/s41598-022-10172-5>
#Globe temperature [C] tg <- 30 #Air temperature [C] ta <- 24 #Air speed [m/s] vel <- 0.0 calcMRT(tg, ta, vel)