calcATHBstandard: PMV based on Adaptive Thermal Heat Balance Framework for the Standard Model

Description

calcATHBstandard calculates the PMV based on adaptive thermal heat balance framework

based on the newest version (2022)

Usage

calcATHBstandard(trm, ta, tr, vel, rh, met)

Value

calcATHBstandard PMV value adapted through the ATHB approach with standard model

Arguments

trm

- Running mean outdoor temperature in [degree C]

ta

- a numeric value presenting air temperature in [degree C]

tr

- a numeric value presenting mean radiant temperature in [degree C]

vel

- a numeric value presenting air velocity in [m/s]

rh

- a numeric value presenting relative humidity [%]

met

- a numeric value presenting metabolic rate in [met]

Author

Code implemented in to R by Shaomi Rahman. Further contribution by Marcel Schweiker.

Details

aliases athb ATHB

References

Schweiker & Wagner (2015) <doi:10.1016/j.buildenv.2015.08.018> Schweiker (2022) <doi:10.1111/ina.13018>

See Also

see also calcComfInd, link{calcATHBpts}, link{calcATHBset},

link{calcATHBpmv2015}

Examples

Run this code
calcATHBstandard(20, 25, 25, .1, 50, 1.1)