kConstant: Hydraulic Conductivity From Constant Head Test (Groundwater)

Description

Computes the hydraulic conductivity from the constant head test. 1 January 2016

Usage

kConstant(V, t, h, L, As = NA, Ds = NA)

Value

Hydraulic conductivity from the constant head test

Arguments

V

= volume of water collected

t

= time of flow

h

= head difference between inflow and outflow

L

= length of soil sample

As

= cross-sectional area of the soil sample

Ds

= diameter of soil sample

Author

Kyle Elmy and Jim Kaklamanos

Examples

Run this code
kConstant(V = 800, t = 100, h = 200, As = 40, L = 50)