Computes the hydraulic conductivity from the constant head test. 1 January 2016
kConstant(V, t, h, L, As = NA, Ds = NA)
Hydraulic conductivity from the constant head test
= volume of water collected
= time of flow
= head difference between inflow and outflow
= length of soil sample
= cross-sectional area of the soil sample
= diameter of soil sample
Kyle Elmy and Jim Kaklamanos
kConstant(V = 800, t = 100, h = 200, As = 40, L = 50) # k in units of cm/s
Run the code above in your browser using DataLab