powered by
Computes the hydraulic conductivity from pumping tests. 1 January 2016
kPump(Q, H = NA, h1, h2, r1, r2)
k = hydraulic conductivity of aquifer
= flow rate into well
= thickness of aquifer
= total head in farthest observation well
= total head in nearest observation well
= radius from pumped well to farthest observation well
= radius from pumped well to nearest observation well
Kyle Elmy and Jim Kaklamanos
kPump(Q = 14.5, H = 10, h1 = 20, h2 = 16, r1 = 16, r2 = 8)
Run the code above in your browser using DataLab