Computes the flow rate to wells. 1 January 2016
wellFlow(k, H = NA, h0, hf, r0, rw)
Q = flow rate to well
= hydraulic conductivity of aquifer
= thickness of aquifer
= initial total head in aquifer (before pumping)
= final total head in well casing (after pumping)
= radius of influence
= radius of well
Kyle Elmy and Jim Kaklamanos
wellFlow(k = 0.065, H = 10, h0 = 21, hf = 15, r0 = 20, rw = 2)