swTSrho: Seawater temperature from salinity and density
Description
Compute in-situ temperature, given salinity, density, and pressure.
Usage
swTSrho(salinity, density, pressure)
Arguments
salinity
in-situ salinity [PSU]
density
in-situ density or sigma value [kg/m$^3$]
pressure
in-situ pressure [dbar]
Value
In-situ temperature [$^\circ C$].
Details
Finds the temperature that yields the given density, with the
given salinity and pressure. The method is a bisection search with
temperature tolerance 0.001 $^\circ C$.
References
Fofonoff, P. and R. C. Millard Jr, 1983. Algorithms for
computation of fundamental properties of seawater. Unesco
Technical Papers in Marine Science, 44, 53 pp
Gill, A.E., 1982. Atmosphere-ocean Dynamics, Academic Press, New
York, 662 pp.