- t1
temperature of heat carrier (water) inside the supplying pipe, [°C].
Type: assert_double
.
- t2
temperature of heat carrier (water) inside the returning pipe, [°C].
Type: assert_double
.
- t0
temperature of environment, [°C]. In case of channel laying this is
the temperature of subsoil. Type: assert_double
.
- insd1
thickness of the insulator which covers the supplying pipe, [m].
Type: assert_double
.
- insd2
thickness of the insulator which covers the returning pipe, [m].
Type: assert_double
.
- d1
outside diameter of supplying pipe, [m]. Type: assert_double
.
- d2
outside diameter of returning pipe, [m]. Type: assert_double
.
- lambda1
thermal conductivity of insulator which covers the supplying pipe
[W/m/°C]. Type: assert_double
.
- lambda2
thermal conductivity of insulator which covers the returning pipe
[W/m/°C]. Type: assert_double
.
- k1
technical condition factor for insulator of supplying pipe, [].
Type: assert_double
.
- k2
technical condition factor for insulator of returning pipe, [].
Type: assert_double
.
- lambda0
thermal conductivity of environment, [W/m/°C]. In case of channel
laying this is the thermal conductivity of subsoil. Type: assert_double
.
- z
channel laying depth, [m]. Type: assert_double
.
- b
channel width, [m]. Type: assert_double
.
- h
channel height, [m]. Type: assert_double
.
- len
length of supplying pipe, [m]. Type: assert_double
.
- duration
duration of heat loss, [hour]. Type: assert_double
.