Learn R Programming

ravetools (version 0.4.2)

register_volume3d: Native 3D volume registration ('rigid', 'affine', or 'SyN')

Description

Self-contained image registration for 3D volumes, implemented purely in RcppEigen (no other external registration library). It mirrors the core behavior of 'ANTs' antsRegistration: a multi-resolution, physical-shift scaled gradient-descent optimizer driving a similarity metric, working entirely in the anatomical RAS (right-anterior-superior) space. Each volume carries its own vox2ras (0-indexed voxel index to anatomical RAS) \(4\times 4\) transform, so volumes with different sampling, orientation, or field of view are aligned correctly.

Usage

register_volume3d(
  source,
  target,
  source_vox2ras = NULL,
  target_vox2ras = NULL,
  source_mask = NULL,
  target_mask = NULL,
  source_points = NULL,
  target_points = NULL,
  points_weight = 0.5,
  weights = NULL,
  type = c("rigid", "affine", "syn", "syn_only"),
  metric = "mattes",
  shrink_factors = c(4, 2, 1),
  smoothing_sigmas = c(2, 1, 0),
  iterations = c(1000, 500, 250),
  sampling_rate = 0.2,
  interpolation = "trilinear",
  number_of_bins = 32L,
  seed = 1L,
  init_transform = NULL,
  syn_iterations = c(40, 20, 0),
  syn_sigma = 3,
  syn_grad_step = 0.2,
  syn_total_sigma = 0,
  syn_cc_radius = 2L,
  syn_convergence = 1e-06,
  syn_convergence_window = 10L,
  verbose = TRUE
)

Value

A list of class ravetools_register_volume3d with:

transform

the estimated 4x4 RAS-to-RAS linear transform mapping target (fixed) coordinates to source (moving) coordinates

image

the (primary) source resampled onto the target grid

images

a list with every source channel resampled onto the target grid using its own interpolation; image is the first element. For single-image input this is a length-1 list

forward_field,inverse_field

(only for "syn") the deformation fields on the target grid, see ‘Details’

metric_trace

the metric value across the optimizer iterations that ran (in the deformable stage, the weighted cost of all channels plus the landmark term, one value per iteration)

syn_iterations_run

(only for "syn" and "syn_only") the number of deformable iterations each level ran; 0 for levels without a positive iteration count

geometry

the source and target grids (source_dim, source_vox2ras, target_dim, target_vox2ras)

type,metric

echoes of the inputs

Arguments

source

the moving volume to be aligned, a 3D array (for example a 'CT'); the result transform maps target into this image's space. May also be a list of already co-registered 3D arrays (multiple modalities such as 'T1', 'T2', an atlas constraint); all source channels must share the same dimensions and vox2ras

target

the fixed/reference volume to align to, a 3D array (for example a 'MRI'), or a list of co-registered arrays matching source channel-for-channel

source_vox2ras, target_vox2ras

4x4 (or 3x4) matrices mapping the 0-indexed voxel coordinate (column-row-slice, 'C'-style starting from 0, complying with 'NIfTI') to the RAS coordinate system; if NULL, the function looks for a "vox2ras" attribute on the array

source_mask, target_mask

optional 3D mask arrays restricting where the metric is evaluated; default NULL (no mask, evaluate everywhere). A target_mask (on the target/fixed grid, same dimensions as target) limits which target voxels drive the registration; a source_mask (on the source/moving grid) drops samples that map outside it. Non-zero voxels are included. Besides focusing the alignment on a region of interest, masks speed things up by skipping background: the linear stage samples only inside the mask, and the deformable stage skips warping voxels outside the (dilated) mask. One mask per grid, shared across channels

source_points, target_points

optional N x 3 matrices of corresponding landmark coordinates that add a surface/landmark term to the deformable ("syn"/"syn_only") stage; default NULL (no term). Row i of target_points (in the target/fixed RAS) and row i of source_points (in the source/moving RAS) must be the same anatomical location, for example corresponding cortical-surface vertices from a 'FreeSurfer' spherical registration. The term pulls the warp of each target point onto its source correspondent, recovering cortical folding (gyrification) that the intensity metric blurs over, while the image metric still drives deep-brain subcortical structures. Must be supplied together with equal row counts. Points must be in the same RAS frame as source_vox2ras/target_vox2ras (note 'FreeSurfer' surfaces use surface/tkr RAS, which differs from scanner RAS by c_ras)

points_weight

relative weight of the landmark term against the image metric in the deformable stage; default 0.5. Larger values follow the landmarks more closely. The sparse landmark force is attenuated by syn_sigma smoothing, so this typically needs tuning for a given point count and spacing

weights

optional numeric weights, one per source/target pair, controlling each channel's contribution to the deformable cost; default is equal weighting. Weights are normalized internally to sum to 1. Only the deformable ("syn"/"syn_only") stage is multivariate; the linear stage always uses the first (primary) pair

type

type of transform to estimate; one of 'rigid' (6 degrees of freedom), 'affine' (12), "syn" (affine followed by a SDR - symmetric diffeomorphic deformation), or 'syn_only' (deformable stage only — no affine is estimated; init_transform is used directly as the starting affine, useful when you already have a good linear alignment)

metric

similarity metric: "mattes" (Mattes mutual information, the default, best for cross-modal such as 'CT'-'MRI'), "cc" (normalized cross-correlation, for same-modality), or "meansquares" (mean squared intensity difference). With multiple channels, supply either a single metric (used for every pair) or a vector with one metric per source/target pair

shrink_factors

integer down-sampling factors, one per resolution level (coarsest first); default c(4, 2, 1)

smoothing_sigmas

Gaussian smoothing applied at each level, in voxels, same length as shrink_factors; default c(2, 1, 0)

iterations

maximum optimizer iterations per level; default c(1000, 500, 250)

sampling_rate

fraction of fixed voxels sampled to evaluate the metric (speeds up large volumes); default 0.2

interpolation

output interpolation used when warping each modality onto the target grid: 'trilinear' (default), 'nearest' (keeps label or segmentation values intact), or "bspline" (cubic Catmull-Rom, higher quality, slower). Like metric, supply a single value (applied to every channel) or one per source/target pair. This affects only the returned warped images, never the optimization's internal sampling (always 'trilinear', so every channel still produces smooth gradients)

number_of_bins

number of histogram bins for the "mattes" metric; default 32

seed

random seed for the voxel sampler, for reproducibility

init_transform

optional 4x4 initial RAS-to-RAS transform (fixed to moving) to start from

syn_iterations, syn_sigma

deformable stage controls (only used when type = "syn" or "syn_only"): per-level iteration counts (the maxima: with syn_convergence, a level ends earlier once its cost stops decreasing) and the Gaussian regularization sigma (in voxels) applied to the update field. Both are recycled to the number of levels, so syn_sigma may be a vector to vary the regularization per stage (e.g. c(3, 3, 1) to relax it at the finest level for sharper detail)

syn_grad_step

deformable stage step size: each update is capped at syn_grad_step times the voxel spacing of the current level; default 0.2 (must be positive)

syn_total_sigma

Gaussian sigma (in voxels) applied to the total deformation field after each update (the elastic-like regularization of 'ANTs' SyN[gradStep, updateFieldSigma, totalFieldSigma]); default 0 (none; must be non-negative)

syn_cc_radius

radius (in voxels) of the local window of the deformable-stage cross-correlation metric; default 2L (a \(5^3\) window; must be an integer of at least 1)

syn_convergence, syn_convergence_window

convergence stop of each deformable level, with the rule of 'ANTs' (--convergence [syn_iterations,syn_convergence,syn_convergence_window]): the threshold, a single finite number (default 1e-6), or NULL to run every iteration of syn_iterations; and the window, the number of recent iterations whose cost trend is tested (an integer of at least 2; default 10L). The defaults are those of antsRegistration; the "SyN" transforms of 'ANTsPy' use 1e-7 and 8L. See ‘Details’

verbose

logical; if TRUE (default) print per-level and per-iteration progress to the console, including the current stage, shrink factor, smoothing sigma, cost metric, and step size (linear) or maximum displacement (deformable), with the convergence stop also the convergence value and why each deformable level ended; useful to monitor convergence on large volumes

Details

Choosing a metric. For a same-contrast pair, such as a native 'T1'-weighted scan against a 'T1' template, the default metric = "mattes" reproduces the 'ANTs' SyN recipe: Mattes mutual information drives the rigid and affine stages and local cross-correlation drives the deformable stage (the "cc" metric only changes the linear stages). The 'ANTs'-like 'T1'-to-template preset is syn_cc_radius = 4, syn_grad_step = 0.15 and syn_sigma = 3.5; the defaults are a faster, lightly regularized variant. For cross-contrast pairs mutual information is the usual choice for the linear stages; the deformable stage has no mutual-information metric, and its squared local correlation tolerates an inverted contrast (such as 'T2' against 'T1') but not a non-monotonic relation (such as FLAIR or 'CT' against 'T1'), so give such channels a low weight in a multichannel call.

Convergence of the deformable stage. With syn_convergence set (the default), every deformable level ends as soon as its cost stops decreasing, by the rule of 'ANTs': the cost of the first channel (without its weight and without the landmark term) is recorded at every iteration and divided by the sum of its absolute values since the level started; once syn_convergence_window values exist, a straight line is fitted through the most recent ones (the B-spline fit of ITK), and the level stops when the fitted decrease across the window falls below syn_convergence. A level therefore runs at least syn_convergence_window iterations (or all of them, if fewer), unless an update vanishes, after which the field cannot change anymore (only with syn_total_sigma = 0); the last update is kept. The window thus sets the minimum number of iterations of a level, and the threshold how flat the trend of the cost must be before the level stops: while the cost still decreases steadily, a level can run to its maximum. Every update has the same size (syn_grad_step times the voxel spacing), so once the deformation settles the cost tends to oscillate, and a level then usually ends a few iterations later. syn_iterations_run in the result gives the iterations each level ran. With syn_convergence = NULL, every iteration runs (the behavior before ravetools 0.4.1).

Deformation fields. forward_field is the displacement \(u_f\) on the target grid such that image samples the source at \(A(r + u_f(r))\). inverse_field is its numerical inverse on the same grid, computed by damped fixed-point iteration (Chen 2008, see ‘References’; at most 20 sweeps, as in 'ANTs'), so \(r + u_f(r) + u_i(r + u_f(r)) \approx r\) and vice versa to within a small fraction of a voxel wherever the forward map is one-to-one inside the target grid. Near the border of an unmasked registration the deformation can fold or push points out of the grid; there the inverse has no exact solution, so inverse_field values at the border are approximate (a target_mask keeps the deformation away from the border). Use apply_transform3d_volume and apply_transform3d_points to apply the result to other volumes or coordinates.

References

Avants B, Epstein C, Grossman M, Gee J (2008). Symmetric diffeomorphic image registration with cross-correlation: evaluating automated labeling of elderly and neurodegenerative brain. Medical Image Analysis, 12(1), 26-41.

Chen M, Lu W, Chen Q, Ruchala K, Olivera G (2008). A simple fixed-point approach to invert a deformation field. Medical Physics, 35(1), 81-88.

See Also

apply_transform3d_volume, apply_transform3d_points, save_registration, resample_3d_volume

Examples

Run this code
# \donttest{

# --- synthetic same-modality example -------------------------------------
nd <- c(50, 50, 50)
vox2ras <- diag(4); vox2ras[1:3, 4] <- -25
blob <- function(cx, cy, cz, s = 6) {
  g <- expand.grid(x = 0:(nd[1]-1), y = 0:(nd[2]-1), z = 0:(nd[3]-1))
  array(exp(-((g$x-cx)^2 + (g$y-cy)^2 + (g$z-cz)^2) / (2*s^2)), nd)
}
target <- blob(25, 25, 25)
source <- blob(28, 23, 26)            # shifted by a known (3, -2, 1) mm

res <- register_volume3d(
  source, target,
  source_vox2ras = vox2ras, target_vox2ras = vox2ras,
  type = "rigid", metric = "cc"
)
res$transform[1:3, 4]                 # ~ c(3, -2, 1)


# --- multimodal registration (several co-registered channels) ------------
# Two aligned modalities (e.g. a T1 and a T2) jointly drive the deformable
# stage. Each pair may use its own metric, and `weights` set their relative
# influence (normalized internally to sum to 1). All source channels must
# share a grid; likewise all target channels.
t1_target <- blob(25, 25, 25, s = 6)
t2_target <- blob(25, 25, 25, s = 9)  # same anatomy, different contrast
t1_source <- blob(27, 24, 26, s = 6)  # both channels share the same warp
t2_source <- blob(27, 24, 26, s = 9)

res_mm <- register_volume3d(
  source = list(t1_source, t2_source),
  target = list(t1_target, t2_target),
  source_vox2ras = vox2ras, target_vox2ras = vox2ras,
  weights = c(2, 1),                  # T1 counts twice as much as T2
  metric = c("mattes", "cc"),         # one metric per channel
  type = "syn"
)
res_mm$transform[1:3, 4]

# }