Learn R Programming

racir (version 2.0.0)

racircalcheck: Allows visual checking of rapid A/Ci response (RACiR) calibration data using empty chamber data.

Description

racircalcheck Used to check range of calibration file. Produces diagnostic graphs of A vs. Ci for quality control. Output includes plots for checking and confirming cutoff values, and a plot with the fit, as well as information as to which polynomial fit the data best.

Usage

racircalcheck(
  data,
  mincut,
  maxcut,
  varnames = list(A = "A", Ca = "Ca", CO2_r = "CO2_r", E = "E", gtc = "gtc")
)

Arguments

data

Data frame with the calibration (empty chamber) rapid A/Ci response

mincut

Minimum cutoff value for reference CO2 (CO2_r). Used to cut out the data from the initial chamber mixing. Default value is set to the minimum COR_r value.

maxcut

Maximum cutoff value for reference CO2 (CO2_r). Used to cut out the data from the end of the response. Not needed in all cases. Default value is set to the maximum COR_r value.

varnames

Variable names - this allows for the use of this code with other machines and setups where variable names may differ.

Value

racircalcheck allows visual checking of RACiR calibration data

Examples

Run this code
# NOT RUN {
#Read in the file
data <- read_6800(system.file("extdata", "cal", package = "racir"))
#Run calibration check
racircalcheck(data = data,
              mincut = 350,
              maxcut = 780)
# }
# NOT RUN {
# }

Run the code above in your browser using DataLab